SHORT SPECIFICATION 

 

  •   4.5" Color LCD Display
  •  Waveform: Biphasic
  • Energy Leval Selection -2 To 200 Joules
  • Charge Time: Less Than 3 Seconds
  •  Adult & Pediatric Paddles Support

 

DESCRIPTION 

The Physio Control Lifepak 20e Defibrillator Is A Clinically Advanced And Packed With Power. The Lifepak 20e Skillfully Combines AED Function With Manual Capability So That ACLS-Trained Clinicians Can Quickly And Easily Deliver Advanced Therapeutic Care.

 

FEATURES 

  • Provides Quick, Effective AED Use.

  • Easily Converts To Manual Modes

  • Compact And Light Weight For Easy Carrying And Versatile Use.

  • Easy To Maintain And Service

  • Waveform: Biphasic Truncated Exponential. The Following Specifications Apply From 25 To 200 Ohms, Unless Otherwise Specified.

  • Energy Accuracy: ±1 Joule Or 10% Of Setting, Whichever Is Greater, Into 50 Ohms ±2 Joule Or 15% Of Setting, Whichever Is Greater, Into Any Impedance From 25–100 Ohms.

  • Voltage Compensation: Active When Disposable Therapy Electrodes Are Attached. Energy Output Within ± 5% Or ± 1 Joule, Whichever Is Greater, Of 50-Ohm Value, Limited To The Available Energy Which Results In The Delivery Of 360 Joules Into 50 Ohms.

 

OPTIONAL  

  • SpO2

  • Pacing

 

DIMENSION 

  • Height: 8.4” (21.3 cm)

  • Width: 10.3” (26.2 cm)

  • Depth: 10.3” (26.2 cm)

  • Weight: 12.3 lbs (5.58 kg)

 

DISPLAY 

  • Size (Active Viewing Area): 115.18 Mm (4.53 In) Wide X 86.38 Mm (3.4 In) High

  • Resolution: 320 X 240 Dot Color Active LCD. Displays A Minimum Of 3.7 Seconds Of ECG And Alphanumeric For Values, Device Instructions Or Prompts Option To Display One Additional Waveform.

  • Waveform Display Sweep Speed: 25 Mm/Sec For ECG And SpO2

 

POWER 

  • The Device Is An AC Line-Operated Device With An Internal Battery As Backup.

  • Ac Powered: 100–120 Vac 50/60hz, 220–240 Vac 50/60 Hz, Total Power Draw Less Than 120 Volt-Amperes (Va).

 

BATTERY 

  • Battery Charge Time: <4 Hours When The Device Is Powered Off And Ac Power Is Applied.

  • Run Time: A New Fully-Charged Internal Backup Battery Will Provide Between 110-210 Minutes Of Run Time Depending On How It’s Being Used.

 

PRINTER 

  • Prints Continuous Strips Of The Displayed Patient Information.

  • Paper Size: 50 Mm (2.0 In)

  • Print Speed: Continuous Ecg 25 Mm/Sec +/- 5% (Measured In Accordance With Aami Ec-11, 4.2.5.2)

  • Delay: 8 Seconds

  • Autoprint: Waveform Events Print Automatically (User Configurable)

  • Print Speed For CODE SUMMARY Reports: 25 mm/sec

 

FREQUENCY RESPONSE

  • Diagnostic: 0.05 to 150 Hz or 0.05 to 40 Hz (User Configurable)

  • Monitor: 0.67 to 40 Hz or 1 to 30 Hz (User Configurable)

  • Paddles: 2.5 to 30 Hz

  • Analog ECG Output: 0.67 to 32 Hz (Except 2.5 to 30 Hz For Paddles ECG)

 

ALARMS       

Quick Set: Activates Alarms For All Parameters

  • VF/VT Alarm: Activates Continuous CPSS Monitoring In Manual Mode

 

ECG

  • ECG Can Be Monitored Through 3-Wire Or 5-Wire ECG Cables.

  • Standard Paddles Or Therapy Electrodes (Quik-Combo Pacing/Defibrillation ECG Electrodes Or Fast-Patch Disposable Defibrillation/Ecg Electrodes) Are Used For Paddles Lead Monitoring.

  • Compatible With LIFEPAK 12 ECG And Therapy Cables.

  • Lead Selection

    • Leads I, II, and III, (3-Wire ECG Cable)

    • Leads I, II, III, AVR, AVL, And AVF, V (c) Acquired Simultaneously, (5-Wire ECG Cable)

  • ECG Size: 4, 3, 2.5, 2, 1.5, 1, 0.5, 0.25 cm/mV

  • Heart Rate Display: 20–300 bpm Digital Display

  • Out Of Range Indication: Display Symbol “—” Heart Symbol Flash For Each QRS Detection

  • Continuous Patient Surveillance System (CPSS): In AED Mode, While Shock Advisory System Is Not Active, CPSS Monitors

  • The Patient Via Quik-Combo Paddles Or Lead Ii ECG For Potentially Shockable Rhythms.Voice Prompts: Used For Selected Warnings And Alarms (Configurable On/Off)

  • Analog ECG Output: 1v/MV X 1.0 Gain < 35 Ms Delay

  • Common Mode Rejection: 90 Db At 50/60 Hz

 

SPO2

  • Masimo Set

  • Additional Configuration Available For Compatibility With Select Nellcor Sensors

  • Saturation Range: 1 To 100%

  • Saturation Accuracy: 70–100% (0–69% Unspecified)

  • Adults/Pediatrics:

    • +/- 2 Digits (During No Motion Conditions)

    • +/- 3 Digits (During Motion Conditions)

  • Neonates:

    • +/- 3 Digits (During No Motion Conditions)

    • +/- 3 Digits (During Motion Conditions)

  • Dynamic Signal Strength Bar Graph

  • Pulse Tone At The Onset Of The Pleth Waveform

  • Spo2 Update Averaging Rate: User Selectable 4, 8, 12, Or 16 Seconds

  • Spo2 Measurement: Functional Sp02 Values Are Displayed And Stored

  • Pulse Rate Range: 25 To 240 Pulses Per Minute

  • Pulse Rate Accuracy: (Adults/Pediatrics/Neonates)

    • +/- 3 Digits (During No Motion Conditions)

    • +/- 5 Digits (During Motion Conditions)

  • Spo2 Waveform With Auto Gain Control

 

COMMUNICATIONS

The Device Is Capable Of Transferring Data Records By IRDA.

 

DATA MANAGEMENT 

  • The Device Captures And Stores Patient Data, Events (Including Waveforms And Annotations), And Continuous ECG Waveform Records In Internal Memory.

  • The User Can Select And Print Reports And Transfer The Stored Information.

 

REPORT TYPES

  • Two Format Types Of CODE SUMMARY Critical Event Record: (Short And Medium)

  • Initial ECG (Except Short Format)

  • Auto Vital Sign Measurements Every 5 Minutes

  • Continuous ECG Waveform Records (Transfer Only)

 

MEMORY CAPACITY

  • Two Full Capacity Patient Records That Include:

  • Code Summary Critical Event Record – Up To 100 Single Waveform Events

  • Continuous Waveform – 45 Minute Continuous ECG Record

Refurbished Biphasic Defibrillator Physio-control® life pack 20

₹102,400.00 Regular Price
₹84,000.00Sale Price
Taxes Included |
  • Easy Return And Exchange Policy

    Non Returnable 

  • Installation

    No Required 

  • Product Condition

    Refurbished 

  • Brand

    Physio - Control 

  • Warranty Policy :

    6 Month's 

  • Delivery Time :

    10 To 15 Day's 