top of page

The EdanUSA X10 Patient Monitor fulfills primary clinical requirements in various environments including emergency rooms, general wards, rehabilitation centers, cardiac intensive care units, and in-hospital transfer units. The X10 comes equipped with a unique 3/5-lead system with automatic chest lead identification, making cardiac monitoring more flexible. iSEAPTM ECG monitoring algorithm with 33 types of arrhythmia detections. SEMIP® ECG diagnosis algorithm with 208 findings

Specifications

High resolution color TFT-LCD screen
Pacemaker detection
Defibrillation and electrosurgical interference protection
Pitch tone (Pulse-tone modulation)
Unique iSEAPTM algorithm which is specially optimized for arrhythmia patients
iMATTM SpO2 algorithm with outstanding motion resistance and low perfusion resistance performance
SP10 Validated NIBP
Built-in rechargeable Li-ion battery
Nurse call
VGA output (optional)
Suitable for adult, pediatric and neonatal patients
Optional: 2-IBP, Respironics CO2, EDAN G2 CO2, Thermal Recorder, WLAN Accessory Kit

Includes:

  • Skin Temperature Probe
  • Reusable SpO2 sensor
  • Adult Cuff
  • NIBP tube with connector
  • 3 lead ECG Cable with Leadwires, Snap (AHA)
  • Rechargeable Lithium-Ion Battery
  • User Manual
  • Ground Cable 

Standard Parameters: 3/5-lead ECG, RESP, EDAN SpO2, EDAN NIBP, PR, 2-TEMP

 

 

Edan X Series Patient Monitor

₹90,000.00 Regular Price
₹84,000.00Sale Price
Taxes Included |
  • Easy Return And Exchange Policy

    Non Returnable 

  • Installation

    No Required 

  • Product Condition

    New 

  • Brand

    EDAN

  • Warranty Policy :

    One Year

  • Delivery Time :

    8 To 15 Day's 

  • ECG

    Lead Type

    3-Lead Or 5-Lead Selectable

    Lead Selection, 3-Lead

    I, II, III

    Lead Selection, 5-Lead

    I, II, III, aVR aVL, aVF. V

    Hr Measurement

    Adult/Pediatric: 15 bpm-300 bpm Neonatal 15 bpm - 300 bpm Step 1 bpm

    Hr Accuracy

    15 bpm or ±1%, Whichever is

    Arrhythmia

    21 calls

    St Measurement Range 

    -25 mV-+2 5 mV

    Waveform Speed

    6.25 mm/s 12.5 mm/s, 25 mm/s,

    Gain Selection

    x 1/4, x 1/2 x 1, x2, x 4, Auto

    Pacemaker Detection

    Yes

  • NON-INVASIVE BLOOD PRESSURE (NIBP)

    Method

    Automatic Oscillometic 

    Parameters

    SYS/DIA/MAP/Pulse Rate

    Operating Mode

    Manual/Auto/STAT

    Auto Measure Intervals 

    3, 5, 10, 15, 30, 60, 90, 120, 240 480 Minutes

    Units

    mmHg/kPa

    Cuff Pressure Range , Adult/ Pediatric 

    0-300 mmHg (0 kPa -40.0 kPa)

    Cuff Pressure Range , Neonatal

    0-150 mmHg (0 kPa - 20.0 kPa)

    Systolic Measurement Range, Adult /Pediatric 

    Systolic Measurement 30mm rig-135 mmHg (4 0 kPa -33.9 kPa)

    Systolic Measurement Range, Neonatal

    30 mmHg -135 mmHg (4.0kPa-18.0 kPa)

    Diastolic Measurement Range , Adult / Pediatric 

    10 mmHg -220 mmHg (1.3 kPa-29.3 kPa)

    Diastolic Measurement Range , Neonatal 

    10 mmHg -110 mmHg (1.3 kPa-14.7  kPa)

    Map Measurement Range , Adult / Pediatric 

    20 mmHg -235 mmHg (2.7  kPa-31.3 kPa)

    MAP Measurement Range ,Neonatal 

    20 mmHg -125 mmHg (2.7 kPa-16.7 kPa)

    Accuracy , Maximum standard Deviation 

    8 mmHg (1.1 kPa)

    Accuracy , Mean Error 

    土5 mmHg (土0.7 kPa)

    Pulse rate Range

    40 bpm -240 bpm

    Pulse Rate Accuracy

    土 5 bpm or 土5%, Whichever is Greater

bottom of page